Splitter Damper for Power Plants
UGES Splitter Dampers for power plants enable efficient division of flue gas and combustion air streams across boiler passes, ESP chambers, and FGD absorber modules. Engineered for high-volume thermal power station ducts, these dampers ensure balanced gas distribution for optimal combustion and emission control performance.
Trusted by the largest brands
Splitter Damper Key Specifications
Blade Material
Corten steel / SA 516 Gr. 70 with Inconel overlay for corrosive flue gas duty
Temperature Rating
Up to 420°C continuous for boiler economizer outlet and SCR inlet ducts
Actuation Type
Heavy-duty electric actuator with fail-safe spring return and position feedback
Size Range
1000 mm × 1000 mm to 5000 mm × 5000 mm for large boiler flue gas ducts
Sealing
Inflatable seal or flexible metallic seal for zero-leakage isolation at ±750 mmWG
Split Ratio
Continuously adjustable 0–100% diversion with positioner feedback to DCS

Industrial Applications
ESP Chamber Gas Balancing
Divides flue gas evenly across multiple ESP fields to maximize particulate collection efficiency and maintain emission compliance.
FGD Module Diversion
Routes flue gas between FGD absorber modules during partial-load operation or module maintenance, ensuring continuous SO2 removal.
Boiler Pass Isolation
Splits or isolates gas flow between parallel superheater and reheater passes during soot blowing or tube-leak repair.
What Our Partners Say
- Industries Served
- 15+
- Years of Experience
- 10+
- Systems Installed
- 500+
- Happy Clients
- 600+
Need the Right Splitter Damper for Your Power Plants?
Our experts visit your site, understand your workflow, and recommend the exact configuration your system needs.
Bulk Material Handling Products for Power Industry
- Rotary Drum Diverter for Power Plants
- Pivoting Chute Diverter for Power Plants
- Swing Gate for Power Plants
- Butterfly Gate for Power Plants
- Slide Plate Gate for Power Plants
- Guillotine Gate for Power Plants
- Knife Gate for Power Plants
- Transfer Chute for Power Plants
- Belt Conveyor System for Power Plants
- Swing Gate Diverter for Power Plants
- Flap Diverter for Power Plants
- Slide Blade Diverter for Power Plants
- Rotary Plug Diverter for Power Plants
- Multi Louvre Damper for Power Plants
- Parallel Damper for Power Plants
- Double Flap Damper for Power Plants
- Wing Pulleys for Power Plants
- Motorized Pulleys Drum Motors for Power Plants
- Shaftless Screw Conveyors for Power Plants
- Vertical Screw Conveyors for Power Plants
- Mixing Screw Conveyors for Power Plants
- Jacketed Screw Conveyors for Power Plants
- Twin Screw Conveyors for Power Plants
- Offset Rotary Airlock Valves for Power Plants
- Live Bottom Screw Conveyors for Power Plants
- Screw Feeders for Power Plants
- Standard Screw Conveyors for Power Plants
- Take-Up Tension Pulleys for Power Plants
- Side Entry Rotary Airlock Valves for Power Plants
- Snub Pulleys for Power Plants
- Blow-Through Rotary Airlock Valves for Power Plants
- Bend Pulleys for Power Plants
- Drop-Through Rotary Airlock Valves for Power Plants
- Tail Pulleys for Power Plants
- Head Drive Pulleys for Power Plants
- Pipe Conveyor Idlers for Power Plants
- Rubber Disc Idlers for Power Plants
- Self-Cleaning Idlers for Power Plants
- Spiral Idlers for Power Plants
- Garland Idlers for Power Plants
- Guide Idlers for Power Plants
- Self-Aligning Idlers for Power Plants
- Impact Idlers for Power Plants
- Return Idlers for Power Plants
- Carrying Idlers for Power Plants