UGES Parallel Dampers provide accurate volume regulation of combustion air and flue gas in U.S. thermal power generation. With synchronized parallel blades and modulating actuator control, these dampers optimize FD fan, ID fan, and PA fan airflow to maintain boiler efficiency across varying load conditions.
Trusted by the largest brands
Parallel Damper Key Specifications
Blade Material
SA 516 Gr. 70 / Corten-A with stellite-tipped edges for erosion resistance
Temperature Rating
Up to 420°C for hot flue gas; ambient to 80°C for FD and PA fan intake
Actuation Type
Electric multi-turn actuator with 4–20 mA modulating signal and DCS integration
Size Range
1000 mm × 1000 mm to 6000 mm × 4000 mm for large power plant ductwork
Blade Configuration
8 to 24 parallel blades with torque tube linkage for uniform modulation
Pressure Drop
Aerodynamic NACA-profile blades, <20 mmWG pressure drop at full-open rated flow

Industrial Applications
FD Fan Discharge Control
Modulates forced-draft fan discharge volume to maintain optimum combustion air supply across boiler load range from 30% to 100% MCR.
ID Fan Inlet Regulation
Controls induced-draft fan inlet flow to maintain furnace negative pressure, preventing puffing and ensuring stable combustion.
PA Fan Volume Modulation
Regulates primary air fan output to coal mills, adjusting pulverized fuel transport air velocity for varying coal quality and boiler load.
Customer Testimonial
- Industries Served
- 15+
- Years of Experience
- 10+
- Systems Installed
- 500+
- Happy Clients
- 600+
Need the Right Parallel Damper for Your Power Plants?
Our experts visit your site, understand your workflow, and recommend the exact configuration your system needs.
Bulk Material Handling Products for Power Industry
- Rotary Drum Diverter for Power Plants
- Pivoting Chute Diverter for Power Plants
- Swing Gate for Power Plants
- Butterfly Gate for Power Plants
- Slide Plate Gate for Power Plants
- Guillotine Gate for Power Plants
- Knife Gate for Power Plants
- Transfer Chute for Power Plants
- Belt Conveyor System for Power Plants
- Swing Gate Diverter for Power Plants
- Flap Diverter for Power Plants
- Slide Blade Diverter for Power Plants
- Rotary Plug Diverter for Power Plants
- Multi Louvre Damper for Power Plants
- Double Flap Damper for Power Plants
- Splitter Damper for Power Plants
- Wing Pulleys for Power Plants
- Motorized Pulleys Drum Motors for Power Plants
- Shaftless Screw Conveyors for Power Plants
- Vertical Screw Conveyors for Power Plants
- Mixing Screw Conveyors for Power Plants
- Jacketed Screw Conveyors for Power Plants
- Twin Screw Conveyors for Power Plants
- Offset Rotary Airlock Valves for Power Plants
- Live Bottom Screw Conveyors for Power Plants
- Screw Feeders for Power Plants
- Standard Screw Conveyors for Power Plants
- Take-Up Tension Pulleys for Power Plants
- Side Entry Rotary Airlock Valves for Power Plants
- Snub Pulleys for Power Plants
- Blow-Through Rotary Airlock Valves for Power Plants
- Bend Pulleys for Power Plants
- Drop-Through Rotary Airlock Valves for Power Plants
- Tail Pulleys for Power Plants
- Head Drive Pulleys for Power Plants
- Pipe Conveyor Idlers for Power Plants
- Rubber Disc Idlers for Power Plants
- Self-Cleaning Idlers for Power Plants
- Spiral Idlers for Power Plants
- Garland Idlers for Power Plants
- Guide Idlers for Power Plants
- Self-Aligning Idlers for Power Plants
- Impact Idlers for Power Plants
- Return Idlers for Power Plants
- Carrying Idlers for Power Plants